How to Set Up the Z+F PROFILER 9012 for First-Time Use

How to Set Up the Z+F PROFILER 9012 for First-Time Use

Introduction

This article provides detailed instructions on setting up the Z+F PROFILER 9012 for the first time. Following these steps will ensure that your device is configured correctly and ready for use.



Steps to Set Up the Z+F PROFILER 9012

1. Unboxing and Components Check

Steps:

  1. Carefully unbox the Z+F PROFILER 9012 and check for all included components:
    • Z+F PROFILER 9012 scanner
    • Transport box
    • Power supply (100V-240V)
    • Power cable (default 5m, other lengths optional)
    • Ethernet cable (default 5m, other lengths optional)
    • Remote-Box (default 5m, other lengths optional)
    • User Manual
    • Software Laser Control
    • Cleaning set

Tips:

  • Ensure all items are present and in good condition.
  • Refer to the included packing list for verification .


2. Assembling the Hardware

Steps:

  1. Place the Z+F PROFILER 9012 on a stable surface.
  2. Connect the power supply to the device.
  3. Attach the Ethernet cable to the appropriate port.
  4. Connect the Remote-Box to the scanner.

Tips:

  • Ensure all connections are secure.
  • Mount the Z+F PROFILER 9012 using at least four screws on the carrier vehicle if applicable .


3. Installing Necessary Software

Steps:

  1. Insert the provided software installation media into your computer.
  2. Follow the on-screen instructions to install the Z+F LaserControl software.
  3. Activate the software license via email.

Tips:

  • Ensure your computer meets the software requirements.
  • Restart your computer after installation for optimal performance .


4. Initial Power-On and Calibration

Steps:

  1. Press and hold the ON/OFF button on the Remote-Box for at least 0.3 seconds.
  2. Wait approximately 20 seconds for the device to power up and the deflection unit to start spinning.
  3. Listen for the audible signal indicating the device is ready.

Tips:

  • Ensure the rotating mirror protective cover is removed before starting.
  • Verify that the cover glass is clean to avoid measurement errors .


5. Connecting to a Computer

Steps:

  1. Connect the Ethernet cable from the scanner to your computer.
  2. Open a web browser on your computer.
  3. Enter the IP address of the scanner (displayed on the Remote-Box) into the browser.

Tips:

  • Make sure your computer's network settings are configured to communicate with the scanner.
  • Use the IP address format: http://<IP> .


Conclusion

By following these steps, you will have successfully set up the Z+F PROFILER 9012 for the first time. Ensuring proper setup and calibration is crucial for optimal performance and accurate data collection. If you encounter any issues, refer to the troubleshooting section of the user manual or contact support for assistance.

Additional Resources

This detailed setup guide ensures that your Z+F PROFILER 9012 is ready for use, providing reliable performance for all your scanning needs.